High-accuracy quartz, usually shortened to HAQ, is quartz timekeeping rated in seconds per year instead of seconds per month. Its history is a contest over the one thing that disturbs a crystal, which is temperature, and over the second thing, which is power. The through-line is the correction: from the first quartz watches, makers moved to higher frequencies, to crystals with flatter temperature curves and then to thermocompensation, which measures the temperature and corrects the count.
A 1979 Seiko Grand Quartz Twinquartz. Seiko was already attacking the temperature problem in the seventies. Photo: Wikimedia Commons, CC BY-SA 3.0.
Where the error comes from
A tuning-fork crystal’s frequency follows a parabola in temperature, with a sensitivity of about 0.035 ppm per square degree Celsius and a peak near 25 °C. Away from the peak the error grows with the square of the distance, so a few degrees are harmless and tens of degrees are not. The crystal also ages: its frequency drifts, mostly in the first few months, and the drift decays logarithmically. One part per million is 0.0864 seconds a day, or about 31.5 seconds a year, which shows how small the errors are that a one-second-a-year rating has to control: about 0.03 ppm. Three routes lead to better accuracy. A higher frequency divides time more finely, and for a given jitter in the electronics, a faster crystal gives a smaller error. A different crystal cut, such as an AT cut, has a much flatter temperature curve. And thermocompensation measures the temperature of the crystal and corrects the count in software.
Thermocompensation
A thermocompensated movement carries a temperature sensor next to the crystal. A microprocessor reads it many times a day and estimates the frequency error from a lookup table made at the factory. A crystal that is running fast gets a lower counting rate, and one running slow a higher rate, so the correction is continuous and needs no adjustment. Aging is handled separately, by assembling the crystal in a clean environment, sealing it and pre-aging it for at least three months. The same correction is the reason a high-accuracy quartz movement keeps its rating on the wrist and in a drawer.
From a minute a year to seconds
The Seiko Quartz Astron of 1969 was accurate to about five seconds a month. In 1970 the Omega Electroquartz with the Beta 21 calibre reached about the same, and about 1,000 were made. In 1974 and 1975 Omega’s Megaquartz calibres, with a 2.4 MHz crystal, were guaranteed at plus or minus 12 seconds a year. Citizen’s Crystron Mega of 1975 is cited by Citizen at plus or minus 3 seconds a year. Thermocompensation was introduced in the 1970s, in the Girard-Perregaux quartz chronometer and in the Omega Megaquartz.
A tuning-fork quartz crystal, the heartbeat of a standard quartz watch. Photo: Wikimedia Commons, CC BY-SA 3.0.
Grand Seiko 9F
Seiko introduced the calibre 9F for Grand Seiko in 1993, with an accuracy of plus or minus 10 seconds a year. The temperature is measured 540 times a day and the integrated circuit compensates for deviations. A twin pulse control motor moves the seconds hand in two steps per second, and a backlash auto-adjust mechanism uses a hairspring-based system to stabilize the hand. The date changes instantly, and the listed models run about three years on a battery. An earlier Grand Seiko, the 95GS, used Twin Quartz in the 1980s and was rated at plus or minus 10 seconds a year.
Citizen: frequency and light
Citizen’s Chronomaster of 1995 was rated at plus or minus 5 seconds a year. On 22 March 2018 at Baselworld, Citizen announced the Cal. 0100 at plus or minus 1 second a year. It uses an AT-cut crystal vibrating at 8.4 MHz (8,388,608 Hz) against 32,768 Hz for a tuning-fork quartz, 256 times faster, and the oscillator adjusts continuously for temperature shifts across minus 20 to plus 60 degrees Celsius. A faster oscillator draws more power, which is why the watch is solar, with an Eco-Drive reserve of 6 months on a full charge. Citizen presented it as a concept model, 33.3 mm across and 2.92 mm thick, and it reached the market in a limited series in 2019.
Longines and others
Longines introduced the Conquest V.H.P. in 1984. The revived model was previewed at Baselworld 2017 and launched in the United States in November 2017. It is rated at plus or minus 5 seconds a year, uses an ETA movement developed for Longines, and combines thermocompensated quartz with gear position detection, which resets the hands after a hard hit or magnetic exposure. The battery lasts four years. Bulova’s Precisionist of 2010 runs its crystal at 262,144 Hz, eight times the standard frequency, and is rated at about 10 seconds a year.
Where it stands
Standard quartz drifts 15 to 30 seconds a month, high-accuracy quartz holds 5 to 10 seconds a year, and the best reach a second a year. The price paid is a shorter battery life, about 2 to 3 years against 3 to 5 for standard quartz, in the movements that rely on a battery.
Sources
- “Ultimate Precision: Announcing the Eco-Drive movement with ±1.0 second annual accuracy,” Citizen
- “Grand Seiko Quartz Movements,” Grand Seiko
- “Longines Conquest V.H.P.,” Watchonista
- “In-Depth: An Engineer’s Technical and Personal Perspectives on Quartz Timekeeping,” Watches by SJX
- “Why Thermocompensated Quartz Watches Are Precise,” Rotate Watches
- “Only ±5 sec/year: The Ultimate Guide to High-End Quartz Watches,” Jamais Vulgaire
Thanks for reading this.